Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38562639

ABSTRACT

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Shoulder Prosthesis , Humans , Arthroplasty, Replacement, Shoulder/methods , Shoulder Joint/surgery , Shoulder/surgery , Scapula , Range of Motion, Articular , Biomechanical Phenomena
2.
J Shoulder Elbow Surg ; 32(11): 2382-2388, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37379965

ABSTRACT

BACKGROUND: The biomechanical changes and treatment guidelines on acromial fracture after reverse shoulder arthroplasty (RSA) are still not well understood. The purpose of our study was to analyze the biomechanical changes with respect to acromial fracture angulation in RSA. METHODS: RSA was performed on 9 fresh-frozen cadaveric shoulders. An acromial osteotomy was performed on the plane extending from the glenoid surface to simulate an acromion fracture. Four conditions of acromial fracture inferior angulation were evaluated (0°, 10°, 20°, and 30° angulation). The middle deltoid muscle loading origin position was adjusted based on the position of each acromial fracture. The impingement-free angle and capability of the deltoid to produce movement in the abduction and forward flexion planes were measured. The length of the anterior, middle, and posterior deltoid was also analyzed for each acromial fracture angulation. RESULTS: There was no significant difference in the abduction impingement angle between 0° (61.8° ± 2.9°) and 10° angulation (55.9° ± 2.8°); however, the abduction impingement angle of 20° (49.3° ± 2.9°) significantly decreased from 0° and 30° angulation (44.2° ± 4.6°), and 30° angulation significantly differed from 0° and 10° (P < .01). On forward flexion, 10° (75.6° ± 2.7°), 20° (67.9° ± 3.2°), and 30° angulation (59.8° ± 4.0°) had a significantly decreased impingement-free angle than 0° (84.2° ± 4.3°; P < .01), and 30° angulation had a significantly decreased impingement-free angle than 10°. On analysis of glenohumeral abduction capability, 0° significantly differed (at 12.5, 15.0, 17.5, and 20.0N) from 20° and 30°. For forward flexion capability, 30° angulation showed a significantly smaller value than 0° (15N vs. 20N). As acromial fracture angulation increased, the middle and posterior deltoid muscles of 10°, 20°, and 30° became shorter than those of 0°; however, no significant change was found in the anterior deltoid length. CONCLUSIONS: In acromial fractures at the plane of glenoid surface, 10° inferior angulation of the acromion did not interfere with abduction and abduction capability. However, 20° and 30° of inferior angulation caused prominent impingement in abduction and forward flexion and reduced abduction capability. In addition, there was a significant difference between 20° and 30°, suggesting that not only the location of the acromion fracture after RSA but also the degree of angulation are important factors for shoulder biomechanics.

3.
Diagnostics (Basel) ; 13(11)2023 Jun 04.
Article in English | MEDLINE | ID: mdl-37296813

ABSTRACT

BACKGROUND AND PURPOSE: Despite the prevalent incidence of re-tear following rotator cuff repair, there is a notable lack of comparative studies investigating the outcomes between patients with re-tear who underwent primary repair versus those who received patch augmentation for large-to-massive tears. We assessed clinical outcomes of these techniques through a retrospective, randomized controlled trial. METHODS: 134 patients diagnosed with large-to-massive rotator cuff tears from 2018 to 2021 underwent surgery; 65 had primary repair and 69 had patch augmentation. A total of 31 patients with re-tears were included, split into two groups; Group A (primary repair, 12 patients) and Group B (patch augmentation, 19 patients). Outcomes were evaluated using several clinical scales and MRI imaging. RESULTS: Most clinical scores improved postoperatively in both groups. No significant difference in clinical outcomes was observed between groups, except for pain visual analog scale (P-VAS) scores. P-VAS scores showed greater decrease in the patch-augmentation group, a statistically significant difference. CONCLUSIONS: for large-to-massive rotator cuff tears, patch augmentation led to greater decreases in pain than primary repair, despite similar radiographic and clinical results. Greater tuberosity coverage of the supraspinatus tendon footprint may impact P-VAS scores.

4.
Orthop J Sports Med ; 11(3): 23259671231151418, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36896097

ABSTRACT

Background: All-suture anchors have been used for primary arthroscopic Bankart repair because of their ability to minimize initial bone loss. Purpose: To evaluate the clinical efficacy of using all-suture anchors in revision arthroscopic labral repair after failed Bankart repair. Study Design: Case series; Level of evidence, 4. Methods: Enrolled in this study were 28 patients who underwent revision arthroscopic labral repair with all-suture anchors after a failed primary arthroscopic Bankart repair. Revision surgery was determined for patients who had a frank redislocation history with subcritical glenoid bone loss (<15%), nonengaged Hill-Sachs lesion, or off-track lesion. Minimum 2-year postoperative outcomes were evaluated using shoulder range of motion (ROM), the Rowe score, the American Shoulder and Elbow Surgeons (ASES) score, apprehension, and the redislocation rate. Postoperative shoulder anteroposterior radiographs were assessed to evaluate arthritic changes in the glenohumeral joint. Results: The mean patient age was 28.1 ± 6.5 years, and the mean time between primary Bankart repair and revision surgery was 5.4 ± 4.1 years. Compared with the number of suture anchors used in the primary operation, significantly more all-suture anchors were inserted in the revision surgery (3.1 ± 0.5 vs 5.8 ± 1.3, P < .001). During the mean follow-up period of 31.8 ± 10.1 months, 3 patients (10.7%) required reoperation because of traumatic redislocation and symptomatic instability. Of patients with symptoms that did not require reoperation, 2 patients (7.1%) had subjective instability with apprehension depending on the arm position. There was no significant change between preoperative and postoperative ROM. However, ASES (preoperative: 61.2 ± 13.3 to postoperative: 81.4 ± 10.4, P < .01) and Rowe (preoperative: 48.7 ± 9.3 to postoperative: 81.7 ± 13.2, P < .01) scores were significantly improved after revision surgery. Eight patients (28.6%) showed arthritic changes in the glenohumeral joint on final plain anteroposterior radiographs. Conclusion: Revision arthroscopic labral repair using all-suture anchors demonstrated satisfactory 2-year clinical outcomes in terms of functional improvement. Postoperative stability was obtained in 82% of patients without recurrent shoulder instability after failed arthroscopic Bankart repair.

5.
Arch Orthop Trauma Surg ; 143(6): 3037-3046, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35804165

ABSTRACT

INTRODUCTION: Neuromuscular electrical stimulation (NMES) is a treatment modality that has been used to accelerate the rehabilitation of patients with neurological damage. However, it is unclear whether NMES of the deltoid can lead to the early restoration of shoulder function after reverse total shoulder arthroplasty (RSA). MATERIALS AND METHODS: In this prospective and randomized study, 88 patients who underwent RSA with the same prosthesis design for cuff tear arthropathy or irreparable rotator cuff tear were assessed. The patients were divided into two groups (NMES group and non-NMES group, 44 patients each). For the NMES group, two pads of the NMES device were placed over the middle and posterior deltoid area, and NMES was maintained for 1 month after surgery. Shoulder functional outcomes and deltoid thickness were compared at 3, 6, and 12 months postoperatively. Shoulder functional outcomes were assessed based on the visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES), and Constant scores and the range of motion (ROM) and power of the affected shoulder. The thickness of the anterior, middle, and posterior deltoid was measured by ultrasonography. RESULTS: A total of 76 patients (NMES group, 33 patients; non-NMES group, 43 patients) were enrolled in the final analysis. The preoperative demographics and status of the remaining rotator cuff of both groups were not significantly different. At postoperative 3 months, the ROM and power of external rotation of the NMES group were significantly greater than those of the non-NMES group (ROM, 36° ± 14° vs. 29° ± 12°; P = .003; power, 4.8 kg ± 1.8 kg vs. 3.8 kg ± 1.0 kg; P < .002). The ROM of external rotation of the NMES group at postoperative 6 months was also greater than that of the non-NMES group (41° ± 12° vs. 34° ± 11°; P = .013). However, there was no significant difference in the VAS, ASES, and Constant scores at all follow-up points despite gradual improvements until 1 year postoperatively. Serial measurements of the thickness of the anterior, middle, and posterior deltoid of both groups did not show significant differences. CONCLUSIONS: Postoperative NMES of the deltoid after RSA contributed to significantly faster ROM restoration and considerable improvement in the power of external rotation. Therefore, NMES following RSA could lead to the early restoration of external rotation and recovery of deltoid function.


Subject(s)
Arthroplasty, Replacement, Shoulder , Rotator Cuff Injuries , Shoulder Joint , Humans , Shoulder/surgery , Shoulder Joint/surgery , Prospective Studies , Treatment Outcome , Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Range of Motion, Articular , Retrospective Studies
6.
Acta Orthop Traumatol Turc ; 56(3): 199-204, 2022 May.
Article in English | MEDLINE | ID: mdl-35703508

ABSTRACT

OBJECTIVE: The aims of the study were (1) to compare outcomes in terms of malunited distal radius bone union in open-wedge corrective osteotomy using autogenous or allogenic bone and (2) to introduce a new parameter that quantifies the rate of the bone union. METHODS: This retrospective study included 22 patients (14 males, 8 females) who underwent open-wedge corrective osteotomy with bone grafting for a malunited distal radius fracture between January 2006 and December 2018 were enrolled. The mean follow-up duration was 57.2 weeks (SD 46.1, range 12-206). All the patients were then divided into 1 of the 2 groups based on the graft material used: autog- enous bone graft group (n=10, 5 males and 5 females) and allogenic bone graft group (n=12, 9 males and 3 females). We introduced the "duration of union/correction gap ratio" to represent the healing potential of each graft materials. Radiologic parameters including initial correction gap, radial inclination, radial length, palmar tilt, and ulnar variance were also measured pre- and postoperatively. Functional outcomes were assessed by grip strength, range of motion, and the disability of the Arm, Shoulder, and Hand score. RESULTS: Of the 22 patients, 16 (72.7%) achieved complete union within 12 weeks, 3 (13.6%) in over 12 weeks, and the other 3 (13.6%) showed nonunion. Excluding the 3 nonunion cases, the mean union duration was 10.6 weeks, and the mean correction gap was 10 mm. The mean correction gap was wider in the autogenous bone graft group, and the mean union duration was longer in the allogenic bone graft group. Autogenous bone grafts had a significantly lower duration of bone union/correction gap ratio than allogenic bone grafts (0.76 vs. 1.61, P < 0.001). According to the correction method (simple open-wedge corrective osteotomy vs. open-wedge corrective oste- otomy OWCO), only duration of bone union/correction gap ratio reflected the actual difference between values. CONCLUSION: Despite autogenous bone graft donor site morbidities, in our study, autogenous bone showed better bone healing potential than allogenic bone. In terms of bone union, autogenous bone has the benefit of better union in larger gaps than allogenic bone. Surgeons can take advantage of the newly introduced "duration of bone union/correction gap ratio" to compare the bone healing potential by graft materials or surgical options. LEVEL OF EVIDENCE: Level IV, Therapeutic Study.


Subject(s)
Fractures, Malunited , Radius Fractures , Bone Transplantation/methods , Female , Follow-Up Studies , Fractures, Malunited/diagnostic imaging , Fractures, Malunited/surgery , Humans , Male , Osteotomy/methods , Radiography , Radius/diagnostic imaging , Radius/surgery , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Range of Motion, Articular , Retrospective Studies , Wrist Joint
7.
J Clin Med ; 11(3)2022 Feb 05.
Article in English | MEDLINE | ID: mdl-35160287

ABSTRACT

The objective of this study was to demonstrate the effect of intravenous (IV) zoledronate administration on rotator cuff healing, retear rate, and clinical outcomes in osteoporotic patients who underwent arthroscopic rotator cuff repair (ARCR) compared with patients with normal bone densities. In this prospective nonrandomized comparative study with propensity score matching, 30 patients who were postoperatively administered IV zoledronate (5 mg) were enrolled as the study group. The control group was matched using 1-to-2 propensity score matching. Radiologic and functional outcomes were evaluated 6 months after surgery. The functional scores in both groups exhibited significant improvement 6 months after surgery. Compared with Group 1 (osteoporosis with IV zoledronate injection) Group 2 (normal bone density) showed significant improvement in their University of California, Los Angeles (UCLA) shoulder score and Constant Shoulder Score (CSS) at 6 months postoperatively. The range of motion improved in both groups at 6 months after surgery. The retear rates according to Sugaya's classification (IV and V) were 13.3% (4 of 30 patients) and 25% (15 of 60 patients) in Groups 1 and 2, respectively, which established a non-inferiority of Group 1 to the control group. The retear pattern according to Rhee's classification in Group 1 was type I in all cases, whereas eight cases of type I and seven cases of type II patterns were observed in Group 2, which was statistically insignificant between the groups. In conclusion, anti-osteoporotic drug use is beneficial for patients with osteoporosis to reduce the failure rate after an ARCR of length > 2 cm, especially in older female patients. Moreover, thorough scrutiny is required to detect osteoporosis in patients with rotator cuff tears, especially in female patients.

8.
Indian J Orthop ; 56(1): 79-86, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35070146

ABSTRACT

PURPOSE: The current study aimed to demonstrate the outcomes of patients with Lichtman stage II and IIIA Kienböck's disease with mild pain and good range of motion (ROM) after conservative management. We hypothesized that we can conservatively manage patients with early-stage Kienböck's disease including those with stage IIIA. PATIENTS AND METHODS: This study is a retrospective case series. Between January 2012 and December 2017, 38 patients were enrolled in this study. The mean follow-up period of conservatively managed group was 49.1 months. The flexion-extension (FE) arc, grip strength, Pain Visual Analog Scale (pVAS), Modified Mayo Wrist Score (MMWS), and disabilities of the arm, shoulder, and hand (DASH) score were determined for functional evaluation. The radiographic parameters were assessed using the Stahl's index and carpal height ratio. The morphological changes in the lunate were also evaluated with plain radiographs. RESULTS: A total of 31 of 38 patients (81.6%) showed favorable outcomes after conservative treatment. The mean pVAS score, MMWS, and DASH score showed statistically significant improvement, as well as the morphology of lunates on the plain radiograph. The mean FE arc was slightly decreased without statistical significance. The grip strength showed improvement with statistical significance. One patient showed the same radiographic morphology, but did not manifest any pain. A total of five (13.2%) patients who experienced aggravated pain and decreased ROM underwent surgical treatment. The other patient required surgical intervention but was provided conservative treatment due to her circumstances. CONCLUSION: Favorable outcomes can be expected in patients with Lichtman stages II and IIIA avascular necrosis of the lunate (Kienböck's disease) with mild pain and good ROM who undergo conservative management. LEVEL OF EVIDENCE: IV.

9.
Clin Orthop Surg ; 13(2): 229-236, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34094014

ABSTRACT

BACKGROUD: Changes in perianchor cysts around the all-suture anchors, which demonstrate distinguished features from the biocomposite anchors, have not been revealed sufficiently. The purpose of this study was to investigate serial changes of perianchor cysts according to the location of the inserted anchor in the glenoid in arthroscopic labral repair using all-suture anchors. METHODS: We enrolled 43 patients who underwent computed tomography (CT) immediately postoperatively and CT arthrogram (CTA) at 1 year or 2 years after arthroscopic labral repair using a 1.3-mm all-suture anchor for recurrent anterior shoulder dislocation with or without a superior labral tear from anterior to posterior and a posterior labral tear. The mean diameter and tissue density (HU) of perianchor cysts were measured depending on the location in the glenoid. Clinical outcomes, labral healing, and redislocation rate were evaluated at 2 years after surgery. RESULTS: On functional assessment, the mean American Shoulder and Elbow Surgeons score and Rowe score improved statistically significantly after surgery (from 47.9 ± 14.3 preoperatively to 90.1 ± 9.6 postoperatively and from 45.3 ± 12.4 preoperatively to 92.2 ± 10.1 postoperatively, respectively; p < 0.01). Postoperative redislocations were found in 2 patients (4.7%). In radiological evaluation, the mean diameter of perianchor cysts at postoperative 1 year (3.24 ± 0.65 mm) was significantly larger than the immediate postoperative diameter; however, there was no significant difference between postoperative 1 year and 2 years (3.23 ± 0.57 mm). Tissue density at the center of cysts demonstrated no significant difference between 1 and 2 year postoperatively (107.7 ± 29.8 HU [superior], 99.7 ± 31.7 HU [anteroinferior], and 105.1 ± 25.0 HU [posterior] vs. 109.1 ± 26.1 HU [superior], 106.4 ± 30.3 HU [anteroinferior], and 111.0 ± 32.9 HU [posterior]). The mean diameter of perianchor cysts in the anteroinferior position was largest compared with that in superior or posterior positions. CONCLUSIONS: Perianchor cysts associated with all-suture anchors enlarged significantly within 1 year after arthroscopic labral repair regardless of the insertion location in the glenoid. However, the size and tissue density of perianchor cysts were similar at postoperative 1 and 2 years, and satisfactory stability and clinical outcomes were obtained.


Subject(s)
Arthroscopy/methods , Cysts/diagnostic imaging , Postoperative Complications/diagnostic imaging , Shoulder Injuries , Shoulder Joint/surgery , Suture Anchors , Adolescent , Adult , Cysts/etiology , Female , Humans , Joint Instability/surgery , Postoperative Complications/etiology , Shoulder Dislocation/surgery , Young Adult
10.
Clin Orthop Surg ; 13(2): 237-242, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34094015

ABSTRACT

BACKGROUD: It has been reported that vitamin D may play an important role in rotator cuff tears. However, there has been limited information about the prevalence of and risk factors for hypovitaminosis D in patients with rotator cuff tears. Therefore, the purpose of current study was to investigate the prevalence of and risk factors for hypovitaminosis D in patients with rotator cuff tears. METHODS: One hundred seventy-six patients (age, 61.9 ± 8.90 years) who underwent arthroscopic rotator cuff repair for a full-thickness tear were enrolled in this retrospective study. Preoperative serum vitamin D levels (25-hydroxyvitamin D) were measured. Hypovitaminosis D was defined as a serum concentration of 25-hydroxyvitamin D < 20 ng/mL. We investigated whether age, sex, height, weight, body mass index, bone mineral density, alcohol consumption, smoking status, and outdoor occupation were associated with hypovitaminosis D. RESULTS: The prevalence of hypovitaminosis D in patients with rotator cuff tears was 44.3% (78/176). The mean serum concentration of 25-hydroxyvitamin D of total patients was 24.7 ± 13.7 ng/mL. A higher serum level of vitamin D was significantly associated with older age (p < 0.001). Young age was an independent risk factor for hypovitaminosis D. The prevalence of hypovitaminosis D was also lower in patients with an outdoor occupation than in those with an indoor occupation (19.0% vs. 31.4%, p = 0.001). CONCLUSIONS: The prevalence of hypovitaminosis D in patients with rotator cuff tears was 44.3%. Age had a significant positive correlation with the serum concentration of 25-hydroxyvitamin D. Young age and indoor working were independent risk factors for hypovitaminosis D in patients with rotator cuff tears. Therefore, the possibility of hypovitaminosis D should be considered for young and indoor working patients who have rotator cuff tears.


Subject(s)
Rotator Cuff Injuries/surgery , Vitamin D Deficiency/epidemiology , Vitamin D/analogs & derivatives , Adult , Age Factors , Aged , Aged, 80 and over , Humans , Middle Aged , Prevalence , Retrospective Studies , Risk Factors , Sex Factors , Vitamin D/blood
11.
J Shoulder Elbow Surg ; 30(11): 2533-2542, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33813010

ABSTRACT

BACKGROUND: This study aimed to compare the clinical outcomes and radiographic parameters of patients after reverse shoulder arthroplasty (RSA) between the Grammont prosthesis and lateralized humeral design prosthesis. METHODS: A total of 114 patients who underwent RSA with a lateralized humeral design (group L; 71 shoulders) and medialized humeral design (group M; 43 shoulders) prosthesis for cuff tear arthropathy or irreparable rotator cuff tear were enrolled. Clinical outcomes including visual analog scale (VAS), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and Constant scores and range of motion (ROM) were serially followed up at postoperative 3, 6, 12, and 24 months. Radiographic parameters were measured to evaluate preoperative and postoperative status. RESULTS: Both prostheses demonstrated similar clinical outcomes and shoulder function preoperatively and at postoperative 2 years (P >.05). However, patients in group M had significantly better postoperative active forward flexion (postoperative 3 months, 115° ± 12° vs. 101° ± 14°; P <.001; 6 months, 125° ± 13° vs. 118° ± 13°; P <.013) and abduction (3 months, 105° ± 12° vs. 98° ± 12°; P = .002); VAS (3 months, 3.1 ± 1.2 vs. 3.7 ± 1.4; P = .031; 6 months, 2.3 ± 1.1 vs. 2.8 ± 1.3; P = .038); ASES (3 months, 64.2 ± 7.0 vs. 60.4 ± 9.2; P = .022; 6 months, 70.6 ± 6.0 vs. 66.6 ± 8.1; P = .007); and Constant scores (6 months, 59.6 ± 6.9 vs. 55.7 ± 9.3; P = .020). Group L showed a significantly lower rate of scapular notching than group M (15.5% vs. 41.8%; P < .001). The position of the proximal humerus in group L was more lateralized and less distalized than in group M after RSA. CONCLUSIONS: RSA with both the Grammont and lateralized humeral design prostheses provided similar shoulder ROM restoration and functional improvements at a minimum of 2 years. However, patients with a humeral lateralized prosthesis showed slower recovery of shoulder function and ROM up to postoperative 6 months despite a lower incidence of scapular notching.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Shoulder Prosthesis , Humans , Humerus/diagnostic imaging , Humerus/surgery , Prostheses and Implants , Prosthesis Design , Range of Motion, Articular , Shoulder , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Treatment Outcome
12.
JSES Int ; 4(3): 694-700, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32939508

ABSTRACT

BACKGROUND: This study aimed to compare the clinical and radiologic outcomes between patients with irreparable cuff tears (ICTs) and those with cuff tear arthropathy (CTA) after reverse total shoulder arthroplasty (RTSA) with a humeral-lateralization prosthesis. METHODS: A total of 127 patients with ICTs and CTA who underwent RTSA were enrolled and matched at a 1:2 ratio by propensity score. Preoperative shoulder function was assessed for all patients. Radiologic parameters including the acromion-deltoid tuberosity (ADT) distance, lateral humeral offset, and scapular notching were evaluated. RESULTS: Thirty-four patients in the ICT group and 68 patients in the CTA group were matched for comparison. Preoperatively, mean active forward flexion in the ICT group (89.7° ± 29.4°) was significantly better than that in the CTA group (65.5° ± 24.0°, P < .001). In the CTA group, fatty infiltration of the supraspinatus was worse (3.7 ± 0.5) and the ADT distance was shorter (134.0 ± 12.0 mm) compared with the ICT group preoperatively (3.3 ± 0.8 [P = .008] and 140.7 ± 12.5 mm [P = .001], respectively). There was no significant difference in postoperative functional or radiologic outcomes between the 2 groups. However, gains in active forward flexion (37.9° in ICT group vs. 61.5° in CTA group, P < .01) and abduction (42.1° in ICT group vs. 60.6° in CTA group, P < .01) were significantly greater in the CTA group than in the ICT group. CONCLUSIONS: Shoulder function was significantly improved after RTSA regardless of the preoperative diagnosis. Postoperatively, radiologic findings were not significantly different between the 2 groups. Due to the fact that preoperative range of motion and rotator cuff status were better in patients with ICTs, improvements in active forward flexion and abduction were significantly greater in patients with CTA.

13.
Diagnostics (Basel) ; 10(10)2020 Sep 25.
Article in English | MEDLINE | ID: mdl-32993014

ABSTRACT

The longitudinal changes in the tibiofibular relationship as the ankle valgus deformity progresses in patients with hereditary multiple exostoses (HME) are not well-known. We investigated the longitudinal changes and associating factors in the tibiofibular relationship during the growing period. A total of 33 patients (63 legs) with HME underwent two or more standing full-length anteroposterior radiographs. Based on the change in ankle alignments, thirty-five patients with an increase in tibiotalar angle were grouped into group V, and 28 patients with a decreased angle into group N. In terms of the change in radiographic parameters, significant differences were noted in the tibial length, the fibular/tibial ratio, and the proximal and distal epiphyseal gap. However, age, sex, initial ankle alignment, location of osteochondroma, and presence of tibiofibular synostosis did not affect the tibiofibular alignment. The tibial growth was relatively greater than the fibular growth and was accompanied by significant relative fibular shortening in the proximal and distal portions. In pediatric patients with HME, age, sex, initial ankle alignment, location of the osteochondroma, and synostosis did not predict the progression of the ankle valgus deformity. However, when valgus angulation progressed, relative fibular shortening was observed as the tibia grew significantly in comparison to the fibula.

14.
J Clin Med ; 9(8)2020 Aug 06.
Article in English | MEDLINE | ID: mdl-32781633

ABSTRACT

The aim of the current study was to evaluate the functional and radiologic outcomes of biocompatible non-absorbable PEEK (polyetheretherketone) and biocomposite (poly-L-lactic acid/poly(lactic-co-glycolic acid) 70% + ß-tricalcium phosphate) anchors, especially in terms of perianchor cyst formation during the first six months postoperatively. We prospectively analysed 29 patients who underwent arthroscopic rotator cuff repair between March and May 2019. Both PEEK and biocomposite suture anchors were used as lateral anchors in one body. Clinical outcomes were assessed using the shoulder range of motion (ROM), visual analogue scale (VAS) for pain and satisfactory score, American Shoulder and Elbow Surgeons (ASES) score, and Simple Shoulder Test (SST). All these were obtained in patients preoperatively at 3 and 6 months after surgery. The imaging evaluation included perianchor cyst formation, anchor absorption, repaired cuff integrity, and retear pattern. All functional outcomes significantly improved over time. The biocomposite anchor had a statistically significant tendency to form higher grades of fluid collection at 3 months after surgery. However, the perianchor cyst reduced by the sixth postoperative month. Six months postoperatively, the functional outcomes were improved after rotator cuff repair and similar degrees of perianchor cyst formation were observed, regardless of the suture anchor material used.

15.
J Arthroplasty ; 35(3): 864-869, 2020 03.
Article in English | MEDLINE | ID: mdl-31708292

ABSTRACT

BACKGROUND: Antibiotic-loaded bone cement (ALBC) is used to deliver antimycobacterial agents into the focal lesion of musculoskeletal tuberculosis. Although kanamycin is currently used as an antimycobacterial agent for the treatment of multidrug-resistant tuberculosis, there is no information about its suitability in ALBC. METHODS: An in vitro experiment was conducted with cylindrical shape of 40 g of bone cement with 1, 2, and 3 g of kanamycin. Eluate (1 mL) was extracted from each specimen to measure the level of elution and antimycobacterial activity on days 1, 4, 7, 14, and 30. The quantity of kanamycin in eluates was evaluated by a liquid chromatography-mass spectrometry system, and the antimycobacterial activity of eluates against Mycobacterium tuberculosis H37Rv was calculated by comparing the minimal inhibitory concentration. The ultimate compression strength was conducted using a material testing system machine (Instron 3366; Instron, Norwood, MA) before and after elution. RESULTS: Eluates from ALBC containing 2 and 3 g of kanamycin had effective antimycobacterial activity for 30 days, whereas eluates from ALBC containing 1 g of kanamycin were partially active until day 30. The pre-eluted compression strength of kanamycin-loaded cement and vancomycin-loaded cement was weaker as they contained a larger amount of antibiotics. There was no statistical difference between the strength of all kanamycin regimens and 1 g of vancomycin in the ultimate compression test. After 30 days of elution, the strength of all kanamycin-loaded cement and vancomycin-loaded cement cylinders was significantly lower than that of initial specimens (P < .05). CONCLUSION: The antimycobacterial activity of ALBC containing more than 2 g of kanamycin was effective during a 30-day period. The ultimate compression strength of bone cement loaded with 1-3 g of kanamycin was comparable with 1 g of vancomycin while maintaining effective elution until day 30.


Subject(s)
Tuberculosis , Vancomycin , Anti-Bacterial Agents , Bone Cements , Humans , Kanamycin , Microbial Sensitivity Tests , Polymethyl Methacrylate
16.
Arthroscopy ; 35(5): 1351-1358, 2019 05.
Article in English | MEDLINE | ID: mdl-30987905

ABSTRACT

PURPOSE: To compare the clinical outcomes and radiological findings at the anchor site after arthroscopic Bankart repair with all-suture anchors and biodegradable suture anchors in patients with recurrent anterior shoulder dislocation. METHODS: The patients who underwent arthroscopic Bankart repair were divided into 2 groups depending on the type of the suture anchor used in different periods. Power analysis was designed based on the postoperative Rowe score. Clinical outcomes, including the Rowe score, American Shoulder and Elbow Surgeons score, subjective instability, and redislocation rates were evaluated. In all patients enrolled, the tunnel diameter of the anchor was assessed with computed tomography arthrogram at 1 year postoperatively. The Institutional Review Board of Ewha Womans University approved this study (no. EUMC 2017-05-058). RESULTS: A total of 67 patients were enrolled: 33 underwent surgery with a 1.3-mm (single-loaded) or 1.8-mm (double-loaded) all-suture anchor (group A), and 34 underwent surgery with a 3.0-mm biodegradable anchor (10.8 mm in length, 30% 1,2,3-trichloropropane/70% poly-lactide-co-glycolic acid) (group B). There were no significant differences in clinical outcomes between groups A and B in the American Shoulder and Elbow Surgeons score (preoperatively, 51.2 ± 13.7 vs 47.7 ± 12.2; 2 years postoperatively, 88.5 ± 12.3 vs 89.7 ± 10.9; P = .667) and Rowe score (preoperatively, 41.4 ± 10.5 vs 41.3 ± 9.4; 2 years postoperatively, 87.9 ± 14.9 vs 88.5 ± 14.6; P = .857). Postoperative redislocation (6.1% vs 5.9%, P = .682) and subjective instability rate (12.2% vs 17.7%, P = .386) of both groups showed no significant difference. Average tunnel diameter increment was significantly greater with the 1.8-mm all-suture anchor (2.8 ± 0.9 mm) than the 1.3-mm all-suture anchor (1.2 ± 0.8 mm) and 3.0-mm biodegradable anchor (0.8 ± 1.2 mm) (P < .001). CONCLUSIONS: Arthroscopic Bankart repair with the all-suture anchor showed comparable clinical outcomes and postoperative stability as the conventional biodegradable suture anchor at 2 years after surgery. Tunnel diameter increment of the all-suture anchor was significantly greater than that of the biodegradable suture anchor at the 1-year computed tomography analysis. Although tunnel diameter increment was greater with the all-suture anchor, it did not influence the clinical outcomes. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Subject(s)
Arthroscopy/methods , Joint Instability/surgery , Shoulder Dislocation/surgery , Shoulder Joint/surgery , Suture Anchors , Tomography, X-Ray Computed , Adolescent , Adult , Arthroplasty/methods , Biocompatible Materials , Elbow Joint/surgery , Female , Humans , Male , Middle Aged , Postoperative Period , Recurrence , Retrospective Studies , Young Adult
17.
Clin Biomech (Bristol, Avon) ; 60: 45-50, 2018 12.
Article in English | MEDLINE | ID: mdl-30316165

ABSTRACT

BACKGROUND: The biomechanical properties of all-suture anchor for labral repair depending on the insertion angle and location are lacking. The purpose of this study was to quantify the biomechanical fixation characteristics of the anchor position and insertion angle of all-suture anchors for arthroscopic Bankart repair. METHODS: Twenty-four fresh frozen cadaveric glenoid were used. All-suture anchors with 1.5-mm diameter were randomly inserted at 2:30, 4:00, and 5:30 o'clock positions on the glenoid edge, with either 30°, 45° or 60° insertion angles to the mediolateral axis of the glenoid. Anchors were preloaded to 5 N and cyclically loaded from 5 N to 20 N for 10 cycles, followed by a load to failure test at 60 mm/min. Permanent, non-recoverable displacement was quantified at the end of the cyclic loading test to yield load. FINDINGS: All-suture anchors implanted at the 2:30 o'clock position of the glenoid provided greater stiffness, yield load, and ultimate load than those inserted at the 4:00 and 5:30 o'clock positions, regardless of the insertion angle. Displacement at yield and ultimate load were similar among the positions and insertion angles (yield load, vs. 4:00, p = 0.01; vs. 5:30, p = 0.045; ultimate load, vs. 4:00, p < 0.01; vs. 5:30, p < 0.01). The insertion angles of 30°, 45° and 60° did not influence mechanical stability between the 4:00 and 5:30 o'clock positions. INTERPRETATION: The insertion angle of all-suture anchors does not significantly affect the stability at antero-inferior quadrant of the glenoid.


Subject(s)
Arthroscopy/methods , Bankart Lesions/physiopathology , Bankart Lesions/surgery , Suture Anchors , Arthroscopy/instrumentation , Biomechanical Phenomena , Cadaver , Female , Humans , Male , Middle Aged , Scapula/surgery , Suture Techniques
18.
Am J Sports Med ; 46(9): 2177-2184, 2018 07.
Article in English | MEDLINE | ID: mdl-29791191

ABSTRACT

BACKGROUND: Recurrent shoulder instability occurs more frequently after soft tissue surgery when the glenoid defect is greater than 20%. However, for lesions less than 20%, no scientific guidance is available regarding what size of bone fragments may affect shoulder functional restoration after bone incorporation. Purpose/Hypothesis: The purpose was to analyze how preoperative glenoid defect size and bone fragment incorporation alter postoperative clinical outcomes, we compared the functional outcomes of shoulders with and without bony Bankart lesion. It was hypothesized that differences in postoperative clinical outcomes between patients with and without bony fragments would be found only in patients with a larger glenoid defect. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 223 patients who underwent arthroscopic stabilization surgery for recurrent anterior shoulder instability were divided into two groups based on the presence of anterior glenoid bone fragments. In each group, postoperative shoulder functional outcomes, sports activity level, and recurrence rates were evaluated according to preoperative glenoid defect size (small, <10%; medium, 10%-15% and 15%-20%; large, >20%). RESULTS: In patients with small or medium defects, no significant differences were found in postoperative clinical outcomes and sports activity levels between the two groups. However, in patients with a large defect, the patients with bone fragments (mean ± SD American Shoulder and Elbow Surgeons [ASES] score, 92.3 ± 2.7; Rowe score, 90.9 ± 5.4) showed significantly superior clinical outcomes compared with patients who did not have fragments (ASES score, 87.3 ± 6.2, P = .02; Rowe score, 84.8 ± 7.3, P = .04). Among patients without bone fragments, recurrence increased significantly with increasing preoperative glenoid defect size (recurrence rates: 0% in small defects, 7.4% in medium defects, 22.2% in large defects), whereas patients with bone fragments showed no tendency for increasing or decreasing recurrence rates (0% in small defects, 7.9% in medium defects, 5.9% in large defects). CONCLUSION: In the treatment of bony Bankart lesion, the effect of bone fragment incorporation was different according to preoperative glenoid defect size. In patients with preoperative glenoid defects less than 20% of the glenoid width, bone fragment incorporation after arthroscopic bony Bankart repair did not alter clinical outcomes, sports activity levels, or recurrence rates, whereas in patients with defects greater than 20% of the glenoid width, bone fragment incorporation improved clinical outcomes and recurrence rates.


Subject(s)
Arthroscopy , Bankart Lesions/surgery , Joint Instability/surgery , Shoulder Dislocation/surgery , Adolescent , Adult , Arthroscopy/methods , Bankart Lesions/diagnostic imaging , Cohort Studies , Female , Humans , Joint Instability/diagnostic imaging , Male , Shoulder Dislocation/diagnostic imaging , Tomography, X-Ray Computed , Young Adult
19.
Arthroscopy ; 34(8): 2287-2293, 2018 08.
Article in English | MEDLINE | ID: mdl-29804952

ABSTRACT

PURPOSE: To evaluate the clinical outcomes and recurrence rates of arthroscopic stabilization procedures in young patients who had recurrent anterior shoulder instability with a glenoid bone erosion more than 20%, and to compare with those in patients with a glenoid bone erosion less than 20%. METHODS: A total of 161 patients who underwent an arthroscopic stabilization procedure for recurrent anterior shoulder instability with anterior glenoid bone erosions and at least 2 years of follow-up were included. Patients were divided into 2 groups based on the glenoid defect size (group I [32 patients]: erosion >20%, group II [129 patients]: erosion <20%). The clinical outcomes were compared using the American Shoulder Elbow Surgeons (ASES) score, Rowe score, and sports/recreation activity level between the 2 groups. Postoperative complications including instability recurrence were documented. RESULTS: The mean glenoid defect size was 22.1 ± 2.1% in group I, and 12.2 ± 3.7% in group II. In group I, clinical outcomes were significantly improved after operation (ASES score: 57.9 ± 14.3 at initial, 88.9 ± 6.2 at the last visit, P = .001; Rowe score: 42.1 ± 15.6 at initial, 87.4 ± 7.6 at the last visit, P = .001). These results were inferior to the clinical outcomes of patients in group II (ASES score: 91.5 ± 12.7, P < .001; Rowe score: 89.3 ± 12.4, P = .01). Postoperative recurrences occurred in 5 patients (15.6%) in group I, whereas patients in group II showed 5.4% of recurrence rate (P = .05). Competent recoveries to sports/recreation activity were achieved in 84.4% of patients in group I. CONCLUSIONS: Arthroscopic stabilization procedures for recurrent anterior shoulder instability in young patients with glenoid bone erosions more than 20% showed satisfactory clinical outcomes and recurrence rate, although these results were inferior to those of patients with glenoid erosions less than 20%. Arthroscopic stabilization procedures can be applied as the primary treatment of recurrent anterior shoulder instability with a large glenoid bone erosion for functional restoration and return to previous sports activity level. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Subject(s)
Arthroscopy/methods , Bone Resorption/complications , Joint Instability/surgery , Shoulder Dislocation/surgery , Shoulder Joint/surgery , Adult , Arthroscopy/rehabilitation , Bone Resorption/pathology , Female , Humans , Joint Instability/complications , Male , Postoperative Complications , Recurrence , Retrospective Studies , Return to Sport , Scapula/pathology , Shoulder Dislocation/complications , Treatment Outcome , Young Adult
20.
Arthroscopy ; 34(5): 1439-1446, 2018 05.
Article in English | MEDLINE | ID: mdl-29366739

ABSTRACT

PURPOSE: To compare the clinical effects of radiofrequency (RF)-based microtenotomy and arthroscopic release of the extensor carpi radialis brevis (ECRB) tendon in patients with recalcitrant lateral epicondylitis through a prospective randomized controlled study. METHODS: A total of 46 patients were randomly assigned to receive arthroscopic release (group A, 24 patients) or RF-based microtenotomy (group B, 22 patients). The visual analog scale (VAS) score for pain, flexion-extension arc, operation time, Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH), Mayo Elbow Performance Score (MEPS), and grip power of groups A and B were compared during the recovery phases for up to 2 postoperative years. RESULTS: Both groups showed statistically significant functional improvement compared with their preoperative grip strength and DASH, VAS, and MEPS scores at 2 years after surgery (P < .05). There were no differences in postoperative pain relief or functional restoration between the 2 groups during the recovery phases, however the mean operation time for group B (41.4 ± 5.2 minutes) was significantly shorter than that for group A (15.6 ± 3.6 minutes, P < .001). In group B, 1 patient underwent revision surgery due to postoperative ECRB rupture, and 1 patient in group A underwent open release for persistent postoperative discomfort. CONCLUSIONS: RF-based microtenotomy for treating recalcitrant lateral epicondylitis provided clinical outcomes comparable with those from arthroscopic release of ECRB tendon during the recovery phase. RF-based microtenotomy is considered as one of the surgical procedures for treating recalcitrant lateral epicondylitis, with the advantages of reliable elbow functional restoration and significantly shorter operation time. LEVEL OF EVIDENCE: Level I, prospective randomized trial.


Subject(s)
Arthroscopy , Radiofrequency Therapy , Tennis Elbow/surgery , Tenotomy/methods , Adult , Arthroscopy/adverse effects , Female , Hand Strength , Humans , Male , Middle Aged , Pain Measurement , Postoperative Complications , Prospective Studies , Surveys and Questionnaires , Tennis Elbow/physiopathology , Tenotomy/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...